In-house spectral libraries
Record retention time and MS/MS spectra for 600 primary metabolites on your own chromatography and instrument.
MSMLS is a metabolite library of 600 authentic standards in seven ready-to-use 96-well plates, supplied at 5 µg per well for LC-MS. Build retention time and MS/MS libraries on your own instrument, confirm identifications against authentic standards and tune your LC-MS methods.
MSMLS, the Mass Spectrometry Metabolite Library of Standards, holds 600 high-purity metabolites spanning primary metabolism. Every compound is pre-weighed, dried and placed in its own well across seven 96-well plates, ready to dissolve and inject.
Laboratories use MSMLS to record retention times and spectra for key metabolites, to optimize mass spectrometry methods, and to qualify instrument sensitivity and limits of detection. Because the standards run on your own chromatography and instrument, the library you build matches your method.
Built for Confident IdentificationPublic spectral databases tell you what a compound can look like. An authentic standard run on your own system tells you exactly where it elutes and how it fragments under your conditions, which is what confident metabolite identification needs.
MSMLS gives you that reference for 600 primary metabolites at once, with every compound linked to HMDB, KEGG, PubChem and ChEBI so results connect straight to pathway and database tools.
> MSMLS covers carboxylic acids and amino acids, biogenic amines and polyamines, nucleotides, coenzymes and vitamins, mono- and disaccharides, and fatty acids, lipids, steroids and hormones.
Unique metabolites in lot 230-23
Alphanumeric positions A1 to H12
Dried weight, enough for multiple injections
High-purity compounds
Search all 600 MSMLS compounds by name, formula, monoisotopic mass, HMDB, KEGG, PubChem or CAS, then filter the list by plate or mass.
Compound list from the lot 230-23 plate map. The plate map can change between lots with compound availability, so check the map supplied with your library.
Explore the MSMLS plate map well by well: pick one of seven 96-well plates and tap any standard to see its formula, mass and HMDB ID.
Polar primary metabolites, dissolved in water with a little methanol.
Polar primary metabolites, dissolved in water with a little methanol.
Polar primary metabolites, dissolved in water with a little methanol.
Polar primary metabolites, dissolved in water with a little methanol.
Polar primary metabolites, dissolved in water with a little methanol.
Dissolved in water first, then ethanol.
Mostly lipid-like compounds in rows A to E.
Using MSMLS takes four steps: spin down the plates, dissolve each plate, inject singly or pooled, then build your library in MLSDiscovery.
Centrifuge each plate at 3000 rpm for 2 to 3 minutes so any loose material settles to the bottom of the wells.
Use 5% methanol in water for plates 1 to 5, water then ethanol for plate 6, and the row-specific solvents for plate 7.
Run 600 single-compound injections for full detail, or pool each row of each plate for 51 simple mixtures.
Process the data in MLSDiscovery to record retention time, mass, spectra, fragments and adducts for every compound.
MSMLS specifications: 600 metabolite standards, Greiner deep-well plates, purity above 95%, a full plate map and MLSDiscovery software.
A confirmed metabolite identification needs more than a database match, because the strength of a name depends on the evidence. Isomers can share the same molecular formula and precursor mass, some have similar fragmentation patterns, and in-source fragments and other interferences can complicate interpretation further.
The original Metabolomics Standards Initiative framework describes four confidence levels: identified metabolites, putatively annotated compounds, putatively characterized compound classes and unknown compounds. For a Level 1 identification of a known metabolite, it calls for at least two independent, orthogonal properties matched to an authentic standard analyzed under identical experimental conditions.
In LC-MS/MS, a practical approach is to compare retention time and fragmentation behavior, supported by precursor mass and the expected ion form. A physical standard such as an MSMLS compound allows that direct measurement in your own laboratory, while a spectral database provides reference information that helps generate or assess candidate assignments.
At least two independent properties, such as retention time and MS/MS spectrum, matched to an authentic standard run under identical conditions. This is where MSMLS standards come in.
Matched to reference data, such as a spectral library, without an authentic standard on your own method.
The compound class is suggested by its properties, but not the exact compound.
Detected and measured, but not yet identified.
Verify metabolite identity with MSMLS in five steps, from documenting the standard to reporting the confidence level of each match.
Choose the proposed compound and likely isomeric alternatives from the plate map, and record the lot, purity, chemical form and preparation conditions.
Use the same column, mobile phases, gradient, temperature and ionization polarity as your samples, and acquire comparable MS/MS data.
Check precursor ion, retention time and diagnostic product ions against acceptance criteria set for your instrument and method.
Review blanks and neighboring peaks, and where useful compare an unspiked sample with one spiked with the standard.
Retain chromatograms, spectra, settings and matching criteria, and state the confidence level and any unresolved ambiguity.
MSMLS applications cover in-house spectral libraries, confident identification, LC-MS method development and detection limit checks.
Record retention time and MS/MS spectra for 600 primary metabolites on your own chromatography and instrument.
Match features in study samples against authentic standards measured under the same conditions.
Test columns, gradients and source settings across a wide range of polarities and a mass range of 72 to 1,356 Da.
Qualify and quantify instrument sensitivity and limits of detection with known, high-purity compounds.
MSMLS standards have been used to build collision cross section libraries of primary metabolites on ion mobility mass spectrometers.
Use the standards to set up and validate rapid quantitative methods for central carbon and nitrogen metabolism.
MSMLS or LSMLS? Both hold the same 600 metabolites in seven plates; MSMLS has 5 µg per well for LC-MS, LSMLS 1 mg for NMR and assays.
MSMLS questions answered: compound count, amount per well, dissolving and pooling, identifiers, storage, software and Level 1 matches.
MSMLS, the Mass Spectrometry Metabolite Library of Standards, is a collection of 600 high-purity small biochemical molecules that span a broad range of primary metabolism. Each compound is supplied pre-weighed and dried at 5 µg per well across seven 96-well plates, ready for mass spectrometry metabolomics.
The current lot (230-23) contains 600 unique small molecule metabolites arranged in seven 96-well plates: 84 on plate 1, 96 on plate 2, 84 on plate 3, 90 on plate 4, 96 on plates 5 and 6, and 54 on plate 7 in rows A to E. Occasionally the plate map changes with compound availability, so always check the plate map for your lot.
Each well contains 5 µg dried weight of a single compound, which is enough for multiple injections.
First spin the plates at 3000 rpm for 2 to 3 minutes so any loose material settles. For plates 1 to 5, add very clean methanol to 5% of the final volume (up to 20 µL), then high-purity water, and pipette up and down 2 to 3 times. For plate 6, add 10% of the final volume as high-purity water, mix, then make up the volume with 100% ethanol. For plate 7, dissolve row A in 100% chloroform, row B in 90% methanol, and rows C to E in 20% DMSO made up with methanol.
No. Injecting each well on its own gives the most detailed library in 600 injections, using volumes of about 100 to 300 µL per well. Alternatively, pool each row of each plate to analyze the whole collection in 51 injections of simple mixtures. Keep the well volume to 100 µL or less, take 5 to 10 µL from each well for the pool and inject 2, 4 or 6 µL. Check the masses across each row first to make sure your chromatography can separate them.
The Excel plate map lists the plate, row and column for every compound, with the compound name, molecular formula, neutral monoisotopic mass, SMILES, KEGG ID, CAS number, HMDB or YMDB ID, METLIN ID, PubChem CID and SID, ChEBI ID and InChIKey.
Both libraries cover the same broad range of primary metabolism in seven 96-well plates. MSMLS supplies 5 µg of each compound, which suits LC-MS retention time and spectral library building. LSMLS supplies 1 mg of each compound for work that needs more material, such as NMR, functional cellular assays and phenotypic screening.
Yes. Besides the full seven-plate library (MSMLS), individual plates are available as MSMLS01 to MSMLS07 through Sigma-Aldrich. Contact IROA for a quote on the full library.
Store the plates at -20 °C. Once dissolved, reseal the plates and keep them at -20 °C, or -80 °C for long-term storage, protected from moisture and light. Avoid repeated freeze and thaw cycles.
MSMLS is supplied with MLSDiscovery, a software tool that collects spectra, retention time, mass and relative intensity for each compound, fragment and adduct, so you can build a physical mass spectral library under your own analytical conditions. It runs on Windows 7 or higher with at least 8 GB of RAM, and your data files must be convertible to mzXML.
MSMLS is designed for mass spectrometry, where 5 µg per compound is ample. For NMR or other work that needs more material per compound, the Large Scale Metabolite Library of Standards (LSMLS) supplies 1 mg per well.
MSMLS supplies the authentic standards that a Level 1 identification needs. Under the Metabolomics Standards Initiative, a known metabolite counts as identified when at least two independent properties, such as retention time and the MS/MS spectrum, match an authentic standard analyzed under identical conditions. Running MSMLS on your own method gives you those reference measurements, while confidence still depends on how specific your method is and how well the evidence is documented.
Accurate mass helps narrow candidate assignments, but it cannot distinguish all compounds with the same formula. Add independent evidence, such as retention time and an MS/MS spectrum, and compare with an authentic standard such as those in MSMLS when seeking a confirmed identification.
No. A spectral library match supports annotation. Under the original Metabolomics Standards Initiative framework, a Level 1 identification requires comparison with an authentic standard analyzed under the same experimental conditions, and an external library hit by itself does not meet that requirement.
No. The analytical method must resolve or otherwise discriminate the alternatives. Some structural or stereochemical assignments need different chromatography or additional analytical evidence, so report only the structural detail the data support.
Many dried compounds naturally have a color, while others are colorless. This is normal and does not indicate a problem with the standard.
MSMLS is cited in published metabolomics research; Bioz scores how often scientists use this metabolite library of standards.
Order the MSMLS metabolite library or single plates, download the plate map and product sheet, and look up key terms and references.
Seven 96-well plates, 600 compounds, plate map, user manual and MLSDiscovery software
Individual MSMLS plates through Sigma-Aldrich
The same compound range at 1 mg per well
Talk to an IROA scientist about building your metabolite library.