13C internal standard for LC-MS metabolomics

IROA-IS IROA Internal Standard Kit: 95% U-13C Yeast Extract Internal Standard

The IROA Internal Standard Kit is a 95% U-13C yeast extract internal standard that corrects ion suppression in LC-MS metabolomics. ClusterFinder then locates, identifies, suppression-corrects and normalizes matched metabolites, so results stay comparable across samples, batches and instruments.

  • Uniform 95% U-13C labeling
  • A labeled counterpart for each shared metabolite
  • Compound-specific ion suppression correction
  • Dual MSTUS sample normalization
  • Biological peaks separated from artifacts
  • About 2 µg of standard per sample
  • No MS/MS needed for experimental samples
  • Mass spectrometry vendor agnostic
95%U-13C labelingUniform carbon-13 yeast extract
90Samples per kitThree vials, about 30 samples each
600 to 1,000BiochemicalsQuantitated, depending on chromatographic modes
2 µgPer sampleAppropriate for most MS platforms

The IROA Internal Standard (IROA-IS) is a lyophilized S. cerevisiae yeast extract uniformly labeled at about 95% carbon-13. It is a true internal standard: you can spike it into any natural-abundance sample, such as cells, tissue biopsies, plant material, blood or urine.

Because each metabolite in the standard co-elutes with the same metabolite in your sample, the two experience the same ionization conditions. ClusterFinder uses that pairing to find and align peaks, calculate a suppression-corrected area for each matched compound and normalize samples against a reference that is the same every day.

You always see raw, suppression-corrected and normalized data, so you can choose the output that fits your experimental design.
02 / The IROA difference

Why 95% Carbon-13?

Why 95% carbon-13? A 95% label gives every metabolite a predictable carbon envelope that ClusterFinder can recognize and use. With comprehensive labeling above 98%, the monoisotopic peak of most compounds is detectable, but the small M-1 peaks are easily lost. At 95% carbon-13 the M-1 peak becomes large: for a six-carbon molecule such as arginine it reaches about 32% of the monoisotopic peak, compared with an M+1 of only about 6% at natural abundance.

That predictable carbon envelope is mathematically calculable. It confirms the number of carbons in each molecule, lets ClusterFinder identify fragments from their parent peaks, and separates peaks of biological origin from artifacts and noise.

ISOTOPE PATTERN SIMULATOR6 carbons

M-1 is 32% of the monoisotopic peak

Move the sliders to see how the M-1 and M-2 peaks shrink as enrichment rises. Calculated from the binomial distribution of carbon-13.

03 / Data fidelity

Correct Suppression Compound by Compound

Ion suppression correction with the IROA-IS works compound by compound: drag the handle to compare measured and corrected signals.

Measured signal
Suppression corrected

Coeluting material changes ionization efficiency, so the same metabolite concentration can give different signals in different samples. A pooled QC describes the pooled matrix; it may not capture the suppression in each individual specimen.

A coeluting isotope-labeled counterpart can support analyte-specific correction when its response tracks that of the analyte. The IROA-IS provides that counterpart for each matched metabolite, and ClusterFinder then applies Dual MSTUS normalization to the suppression-corrected data.

Suppression correction addresses metabolite-specific losses; normalization addresses sample-level differences such as dilution. Conceptual illustration, not study data.

04 / Compound list

Compounds Routinely Identified in the Standard

See the 230 compounds routinely identified in the IROA internal standard, from amino acids and nucleotides to carbohydrates and peptides.

230compounds
  • 2'-deoxyadenosine
  • 3',5'-cyclic amp
  • 3-methylthiopropylamine
  • 5-(carboxymethylaminomethyl)uridine
  • 5-hydroxymethyl-4-methyluracil
  • 5-methylcytidine
  • 7-methylguanine
  • adenosine
  • adenosine 3',5'-diphosphate
  • adenosine monophosphate
  • aica-riboside
  • cysteineglutathione disulfide
  • cytidine
  • cytidine 2',3'-cyclic phosphate
  • cytidine monophosphate
  • cytosine
  • dihydrouracil
  • guanine
  • guanosine
  • guanosine 3',5'-cyclic monophosphate
  • guanosine diphosphate
  • guanosine monophosphate
  • hypoxanthine
  • inosine
  • uracil
  • uridine
  • uridine 2',3'-cyclic phosphate
  • uridine 5'-diphosphate
  • uridine 5'-monophosphate
  • xanthine

The peptide group is a partial list. The number of compounds detected in a particular experiment depends on extraction, chromatography, ionization, sensitivity and the sample matrix.

Download the list (PDF)

05 / Protocol

Sample Preparation Checklist

Prepare samples with the IROA-IS in six steps: calibrate, dissolve the standard, dry and spike each sample, add a blank, then analyze.

0of 6 steps checked
  1. Step 010.5X to 3X

    Run a calibration pilot

    For each new sample type, test aliquots from half to three times your usual amount against the same amount of IROA-IS, in triplicate.

  2. Step 02900 µL

    Dissolve the standard

    Add re-solvation solvent to an amber vial, mix and vortex, and keep the solution on ice until use.

  3. Step 03Nitrogen

    Dry your sample aliquots

    Dry each aliquot, in the amount set by the calibration, under a gentle nitrogen stream.

  4. Step 0430 µL

    Spike every sample

    Add the IROA-IS solution to each dried sample and vortex. Filter after re-solvation if your method includes it.

  5. Step 053 to 4 injections

    Include an IS-only blank

    Inject a blank that received only internal standard at random points in the sequence, as a QA/QC sample.

  6. Step 06No MS/MS

    Analyze and process

    Run your positive and negative reversed-phase or HILIC modes, then process the data in ClusterFinder.

06 / Specifications

What Is in the Box

The IROA Internal Standard Kit includes three vials of 95% U-13C yeast extract, ClusterFinder software and a manual for 90 samples.

Internal standard
3 vials of lyophilized 95% U-13C S. cerevisiae yeast extract
Software
ClusterFinder, with the library of IROA peaks and their physical characteristics
Documentation
User manual
Capacity
90 experimental samples, about 30 per vial
Amount per sample
About 2 µg of standard in 30 µL of solution
Storage
-80 °C, protected from light
  • Suppression-corrected measurements
  • Dual MSTUS normalization
  • Isotope-pattern filtering of artifacts
  • Fragments linked to parent peaks
  • Mass spectrometry vendor agnostic
08 / Choose your kit

IROA Internal Standard Kit or TruQuant?

IROA Internal Standard Kit or TruQuant? Both include the IROA-IS and ClusterFinder; TruQuant adds a Long-Term Reference Standard.

Full workflow

TruQuant Workflow Kit

Adds a reference standard injected about every ten samples for your own dictionary and instrument QC.

  • Included: 95% U-13C yeast extract internal standard
  • Included: ClusterFinder software
  • Included: Ion suppression correction and Dual MSTUS normalization
  • Included: 90 experimental samples
  • Included: Long-Term Reference Standard (5% and 95% 13C)
  • Included: Reference dictionary and recurring instrument QC
Explore TruQuant
09 / Peer-reviewed evidence

What the Studies Found

Published evidence for the IROA internal standard: three peer-reviewed studies on ion suppression, batch correction and lab agreement.

8% to 1%Sample-to-sample RSD, core compounds
Analytical Chemistry, 2026

Batch-to-batch error correction

Six weekly batches with deliberately introduced disturbances, corrected while preserving treatment-related differences.

0.87Mean inter-laboratory correlation
Analytical Chemistry, 2026

Eight-laboratory reproducibility

Eight US and UK laboratories using their own LC-MS methods differentiated known sample mixtures with suppression-corrected data.

10 / Answers

IROA Internal Standard Questions Answered

IROA Internal Standard questions answered: 95% labeling, compound numbers, samples per kit, preparation, calibration and storage.

What is the IROA Internal Standard?

The IROA Internal Standard (IROA-IS) is a lyophilized yeast extract from Saccharomyces cerevisiae, uniformly labeled at about 95% carbon-13 and 5% carbon-12. Added to every experimental sample, it gives ClusterFinder a labeled counterpart for each shared metabolite, which is used to locate, identify, suppression-correct and normalize the matching natural-abundance signals.

Why is the standard labeled at 95% and not 99% carbon-13?

At 95% carbon-13 every molecule carries a strong M-1 peak next to its monoisotopic peak. For a six-carbon molecule such as arginine the M-1 peak is about 32% of the monoisotopic peak, while with comprehensive labeling above 98% such minor peaks are easily lost. This predictable carbon envelope tells ClusterFinder how many carbons a compound has and separates peaks of biological origin from artifacts.

How many metabolites can be measured with the IROA-IS?

Together with ClusterFinder, the IROA-IS is used to co-locate, identify and quantitate about 600 to 1,000 biochemicals in experimental samples, depending on the chromatographic modes used. The number detectable in a particular experiment depends on extraction, chromatography, ionization, sensitivity and the sample matrix.

How many samples does one kit cover?

One kit contains three vials of IROA-IS, and each vial is expected to be suitable for 30 samples, so the kit covers 90 experimental samples.

How much internal standard goes into each sample?

The workflow protocol delivers approximately 2 µg of the 95% U-13C standard per sample, which should be appropriate for most mass spectrometry platforms. A calibration experiment confirms the right balance between your sample amount and the standard.

How do I prepare the IROA-IS?

Add 900 µL of re-solvation solvent, either the initial chromatographic solvent without acid or water, to an amber vial, mix and vortex. Keep the solution on ice. Dry each sample aliquot under a gentle nitrogen stream and add 30 µL of the IROA-IS solution, then vortex. Because the more polar compounds do not dissolve in relatively non-polar solvents, choose the solvent in your calibration experiment.

Do I need a calibration experiment?

Yes, the first time you use a sample type such as plasma, urine, cells or tissue with the method. The pilot experiment tests different amounts of your prepared sample against the same amount of IROA-IS, so you only need to do it once for each sample type or SOP.

What is the IS-only sample?

It is a blank tube with no experimental material that receives the same aliquot of internal standard. Inject it three or four times at random within your sample sequence; it serves as a QA/QC sample and adds qualitative and quantitative information.

Do I need MS/MS data for every sample?

No. There is no need to collect MS/MS data for the experimental samples. Identification relies on the reference dictionary built from the Long-Term Reference Standard, which has the same chemical makeup and chromatographic behavior as the IROA-IS.

Does the internal standard correct every peak?

Compound-specific suppression correction needs a matching labeled signal, so it applies to metabolites present in the IROA-IS. Dual MSTUS sample normalization can also be applied to other peaks, but that does not make it a compound-specific suppression correction for them. The IROA-IS can also be used to build a retention index for tracking compounds not identified in the standard.

What is the difference between the IS Kit and TruQuant?

The IS Kit contains the IROA-IS and ClusterFinder for 90 samples. The TruQuant Workflow Kit adds the Long-Term Reference Standard, a 1:1 mixture of 5% and 95% carbon-13 extracts that you inject about every ten samples to build your own reference dictionary and monitor instrument performance.

How should the kit be stored?

Store the IROA-IS at -80 °C, protected from light.

Have a question about your matrix or instrument?

Ask a scientist
11 / Get started

Order, Download and Learn More

Order the IROA Internal Standard Kit, download the product sheet and protocols, and look up glossary terms and related products.

IROA-ISIROA Internal Standard Kit

3 vials of 95% U-13C yeast extract, ClusterFinder and user manual, for 90 samples. Price: $100 per 90-sample kit.

WORKFLOWTruQuant Workflow Kit

Adds the Long-Term Reference Standard for your own reference dictionary and instrument QC

12 / References

Scientific References

Scientific references behind the IROA internal standard methods, from MSTUS normalization to the 2025 and 2026 validation studies.

  1. 2025Ion suppression correction and normalization for non-targeted metabolomicsMahmud I, Wei B, Veillon L, et al.Nature Communications 16, 1347
  2. 2026Achieving effective batch-to-batch error correction through suppression correction and Dual MSTUS normalizationGhosh D, Kar J, de Jong FA, Beecher C, Shulaev V.Analytical Chemistry 98, 10966 to 10977
  3. 2026Metabolomic profiles reproducibly differentiate heterogeneous sample mixtures: a multi-lab round robin studyChatelaine H, Balcells C, Barnes S, et al.Analytical Chemistry
  4. 2009Normalization strategies for metabonomic analysis of urine samplesWarrack BM et al. The MSTUS normalization that Dual MSTUS builds on.Journal of Chromatography B
13 / Citations

Trusted in Published Research

The IROA internal standard is cited in published metabolomics research; Bioz scores how often scientists use this labeled standard.

One standard in every sample. Data you can compare.

Talk to an IROA scientist about your matrix, instrument and study design.