Untargeted and semi-targeted profiling
Locate and align IROA-labeled peaks in every sample and identify matched metabolites with ClusterFinder.
The IROA Internal Standard Kit is a 95% U-13C yeast extract internal standard that corrects ion suppression in LC-MS metabolomics. ClusterFinder then locates, identifies, suppression-corrects and normalizes matched metabolites, so results stay comparable across samples, batches and instruments.
The IROA Internal Standard (IROA-IS) is a lyophilized S. cerevisiae yeast extract uniformly labeled at about 95% carbon-13. It is a true internal standard: you can spike it into any natural-abundance sample, such as cells, tissue biopsies, plant material, blood or urine.
Because each metabolite in the standard co-elutes with the same metabolite in your sample, the two experience the same ionization conditions. ClusterFinder uses that pairing to find and align peaks, calculate a suppression-corrected area for each matched compound and normalize samples against a reference that is the same every day.
You always see raw, suppression-corrected and normalized data, so you can choose the output that fits your experimental design.
Why 95% carbon-13? A 95% label gives every metabolite a predictable carbon envelope that ClusterFinder can recognize and use. With comprehensive labeling above 98%, the monoisotopic peak of most compounds is detectable, but the small M-1 peaks are easily lost. At 95% carbon-13 the M-1 peak becomes large: for a six-carbon molecule such as arginine it reaches about 32% of the monoisotopic peak, compared with an M+1 of only about 6% at natural abundance.
That predictable carbon envelope is mathematically calculable. It confirms the number of carbons in each molecule, lets ClusterFinder identify fragments from their parent peaks, and separates peaks of biological origin from artifacts and noise.
M-1 is 32% of the monoisotopic peak
Move the sliders to see how the M-1 and M-2 peaks shrink as enrichment rises. Calculated from the binomial distribution of carbon-13.
Ion suppression correction with the IROA-IS works compound by compound: drag the handle to compare measured and corrected signals.
Coeluting material changes ionization efficiency, so the same metabolite concentration can give different signals in different samples. A pooled QC describes the pooled matrix; it may not capture the suppression in each individual specimen.
A coeluting isotope-labeled counterpart can support analyte-specific correction when its response tracks that of the analyte. The IROA-IS provides that counterpart for each matched metabolite, and ClusterFinder then applies Dual MSTUS normalization to the suppression-corrected data.
Suppression correction addresses metabolite-specific losses; normalization addresses sample-level differences such as dilution. Conceptual illustration, not study data.
See the 230 compounds routinely identified in the IROA internal standard, from amino acids and nucleotides to carbohydrates and peptides.
No compounds match that search.
The peptide group is a partial list. The number of compounds detected in a particular experiment depends on extraction, chromatography, ionization, sensitivity and the sample matrix.
Prepare samples with the IROA-IS in six steps: calibrate, dissolve the standard, dry and spike each sample, add a blank, then analyze.
For each new sample type, test aliquots from half to three times your usual amount against the same amount of IROA-IS, in triplicate.
Add re-solvation solvent to an amber vial, mix and vortex, and keep the solution on ice until use.
Dry each aliquot, in the amount set by the calibration, under a gentle nitrogen stream.
Add the IROA-IS solution to each dried sample and vortex. Filter after re-solvation if your method includes it.
Inject a blank that received only internal standard at random points in the sequence, as a QA/QC sample.
Run your positive and negative reversed-phase or HILIC modes, then process the data in ClusterFinder.
The IROA Internal Standard Kit includes three vials of 95% U-13C yeast extract, ClusterFinder software and a manual for 90 samples.
IROA internal standard applications include untargeted profiling, suppression-corrected quantitation and comparable data across batches.
Locate and align IROA-labeled peaks in every sample and identify matched metabolites with ClusterFinder.
Correct matrix-related signal losses for each metabolite that has a labeled counterpart in the standard.
Normalize to a standard that is the same every day, so samples run weeks apart can be compared.
Keep peaks that carry the IROA carbon envelope and filter out artifacts and noise.
Use the IROA-IS to build a retention index for compounds not identified in the standard.
Repeat the analysis in positive and negative reversed-phase and HILIC modes with the same spiked samples.
IROA Internal Standard Kit or TruQuant? Both include the IROA-IS and ClusterFinder; TruQuant adds a Long-Term Reference Standard.
For labs that want suppression correction and normalization with their own QC routine.
Adds a reference standard injected about every ten samples for your own dictionary and instrument QC.
Published evidence for the IROA internal standard: three peer-reviewed studies on ion suppression, batch correction and lab agreement.
IROA Internal Standard questions answered: 95% labeling, compound numbers, samples per kit, preparation, calibration and storage.
The IROA Internal Standard (IROA-IS) is a lyophilized yeast extract from Saccharomyces cerevisiae, uniformly labeled at about 95% carbon-13 and 5% carbon-12. Added to every experimental sample, it gives ClusterFinder a labeled counterpart for each shared metabolite, which is used to locate, identify, suppression-correct and normalize the matching natural-abundance signals.
At 95% carbon-13 every molecule carries a strong M-1 peak next to its monoisotopic peak. For a six-carbon molecule such as arginine the M-1 peak is about 32% of the monoisotopic peak, while with comprehensive labeling above 98% such minor peaks are easily lost. This predictable carbon envelope tells ClusterFinder how many carbons a compound has and separates peaks of biological origin from artifacts.
Together with ClusterFinder, the IROA-IS is used to co-locate, identify and quantitate about 600 to 1,000 biochemicals in experimental samples, depending on the chromatographic modes used. The number detectable in a particular experiment depends on extraction, chromatography, ionization, sensitivity and the sample matrix.
One kit contains three vials of IROA-IS, and each vial is expected to be suitable for 30 samples, so the kit covers 90 experimental samples.
The workflow protocol delivers approximately 2 µg of the 95% U-13C standard per sample, which should be appropriate for most mass spectrometry platforms. A calibration experiment confirms the right balance between your sample amount and the standard.
Add 900 µL of re-solvation solvent, either the initial chromatographic solvent without acid or water, to an amber vial, mix and vortex. Keep the solution on ice. Dry each sample aliquot under a gentle nitrogen stream and add 30 µL of the IROA-IS solution, then vortex. Because the more polar compounds do not dissolve in relatively non-polar solvents, choose the solvent in your calibration experiment.
Yes, the first time you use a sample type such as plasma, urine, cells or tissue with the method. The pilot experiment tests different amounts of your prepared sample against the same amount of IROA-IS, so you only need to do it once for each sample type or SOP.
It is a blank tube with no experimental material that receives the same aliquot of internal standard. Inject it three or four times at random within your sample sequence; it serves as a QA/QC sample and adds qualitative and quantitative information.
No. There is no need to collect MS/MS data for the experimental samples. Identification relies on the reference dictionary built from the Long-Term Reference Standard, which has the same chemical makeup and chromatographic behavior as the IROA-IS.
Compound-specific suppression correction needs a matching labeled signal, so it applies to metabolites present in the IROA-IS. Dual MSTUS sample normalization can also be applied to other peaks, but that does not make it a compound-specific suppression correction for them. The IROA-IS can also be used to build a retention index for tracking compounds not identified in the standard.
The IS Kit contains the IROA-IS and ClusterFinder for 90 samples. The TruQuant Workflow Kit adds the Long-Term Reference Standard, a 1:1 mixture of 5% and 95% carbon-13 extracts that you inject about every ten samples to build your own reference dictionary and monitor instrument performance.
Store the IROA-IS at -80 °C, protected from light.
Have a question about your matrix or instrument?
Ask a scientistOrder the IROA Internal Standard Kit, download the product sheet and protocols, and look up glossary terms and related products.
3 vials of 95% U-13C yeast extract, ClusterFinder and user manual, for 90 samples. Price: $100 per 90-sample kit.
Adds the Long-Term Reference Standard for your own reference dictionary and instrument QC
Scientific references behind the IROA internal standard methods, from MSTUS normalization to the 2025 and 2026 validation studies.
The IROA internal standard is cited in published metabolomics research; Bioz scores how often scientists use this labeled standard.
Talk to an IROA scientist about your matrix, instrument and study design.