Authentic metabolite standards

Metabolite Libraries of Standards for LC-MS and NMR

IROA metabolite libraries of standards cover primary metabolism, lipids, microbiome, cancer and plant compounds in 96-well plates. Search any compound across every library, then pick the plates that fit your study.

Library Mass Spectrometry Metabolite Library 600 standards Seven plates
10Libraries
>95%Purity
96Wells a plate
Metabolite libraries

What Are Metabolite Libraries of Standards?

Metabolite libraries are sets of authentic, well characterized standards used to identify and quantify small molecules in complex samples.

Run on your own LC-MS method, each standard records the retention time, mass and spectrum that a metabolite gives on your instrument. Matching real samples against those records turns an unknown peak into a confirmed compound.

IROA plates every standard dried and pre-weighed in 96-well plates, with the plate map and MLSDiscovery software to build that reference library quickly.

1,500+Different standards across the ten libraries
>95%Purity of every standard
LC-MS | GC-MS | NMRPlatforms the libraries serve
Compound finder

Which IROA Library Has My Metabolite?

Search every metabolite standard in the IROA libraries by name, formula or HMDB ID and see each library that holds it.

Try
1,501different standards across the libraries
10libraries searched at once
693standards found in more than one library

  • 5-HydroxytryptophanC11H12N2O3 · 220.0848 Da
  • 5-Methoxy-DL-tryptophanC12H14N2O3 · 234.1004 Da
  • Alanyl-TryptophanC14H17N3O3 · 275.1270 Da
  • L-TryptophanamideC11H14ClN3O · 239.0825 Da
  • N-AcetyltryptophanC13H14N2O3 · 246.1004 Da
  • TryptophanC11H12N2O2 · 204.0899 Da

Built from the current plate map of each library. Compounds are matched by HMDB ID, or by name where there is none.

Choose a library

The Right Metabolite Library for Your Research

Pick your research area to see which metabolite library of standards to start with and which one to add next.

Start withMSMLSMass Spectrometry Metabolite Library

MSMLS covers the primary metabolites most untargeted LC-MS studies report, from amino acids and sugars to nucleotides and organic acids.

Open the library
Add nextAAPMLS

Adds dipeptides and modified amino acids that MSMLS does not hold.

All libraries

Compare Every IROA Metabolite Library

Compare the IROA metabolite libraries by compound count, plates, amount per well, chemistry and direct price.

Sort by
LibraryCompoundsPlatesPer wellChemistryPrice
MSMLSMass Spectrometry Metabolite Library60075 µgPrimary metabolites across central metabolism$6,050
LSMLSLarge Scale Metabolite Library60071 mgThe MSMLS metabolites at milligram scale$18,700
PHYTOMLSPhytochemical Library36645 µgFlavonoids, terpenes, alkaloids and plant phenolics$5,042
GUTMLSMicrobiome Metabolite Library18525 µgBacterial, dietary and host metabolites$2,750
AAPMLSAmino Acid and Peptide Library16825 µgDipeptides and modified amino acids$2,198
BACSMLSBile Acid, Carnitine and Sterol Library9615 µgBile acids, acylcarnitines and sterols$1,830
FAMLSFatty Acid Library9615 µgFatty acids from short chain to C30$1,610
ONCOMLSOncometabolite Library9615 µgCancer metabolism and oncometabolites$1,650
OAMLSOrganic Acid Library9615 µgOrganic acids, TCA cycle and indoles$1,380
PPMLSPolyphenol Library8015 µgFlavonoids, phenolic acids, lignans and stilbenes$1,400

Prices are direct from IROA Technologies in US dollars. Compound counts follow the current plate map of each library.

From sample to insight

How a Metabolite Library Turns Peaks Into Answers

A metabolite library of standards fits into your workflow in five steps, from running the plates to biological insight.

  1. 01

    Run the standards

    Dissolve the plates, pool rows if you like and run them on your own LC-MS method.

  2. 02

    Build your library

    MLSDiscovery records the retention time, mass and spectrum of every standard from the plate map.

  3. 03

    Analyze your samples

    Run your biological samples with the same method and instrument settings.

  4. 04

    Match with confidence

    Peaks that match a standard on mass and retention time are identified at the highest confidence level.

  5. 05

    Biological insights

    Confirmed identities make pathway and biomarker results you can report and repeat.

Shared standards

How Much the Libraries Overlap

Metabolite libraries share some standards, and this chart counts the compounds every pair of IROA libraries has in common.

Most standards belong to one library only. The overlaps sit where chemistry meets, such as the phenolic acids found in both the microbiome and phytochemical plates, or the organic acids shared with MSMLS.

Use it when you build a set of libraries, so each new plate adds compounds you do not already have. LSMLS is left out because it holds the same compounds as MSMLS.

Point at a square to see how many standards two libraries share.

MSBACSFAOAAAPGUTPPONCOPHYTOMSBACSFAOAAAPGUTPPONCOPHYTO

Counted from the current plate maps, matching compounds by HMDB ID, or by name where there is none.

In every box

What Every IROA Metabolite Library Includes

Every IROA metabolite library of standards ships with the same essentials, whichever chemistry it covers.

Plate map

Every well listed with name, formula, mass and database IDs, ready to load into your software.

MLSDiscovery software

Matches your runs to the plate map so each standard gets its retention time and spectrum.

Above 95% purity

Each standard is checked for purity before it is weighed into the plate.

Pre-weighed and dried

5 µg per well, or 1 mg in LSMLS, dried so the plates ship and store well.

Pool by row

Pool each row into one mixture to screen a whole plate in a handful of injections.

Made by IROA

IROA Technologies builds every library, so you buy direct from the manufacturer.

Questions

Metabolite Library Questions Answered

Answers about IROA metabolite libraries of standards, from choosing a first library to overlap, contents and instruments.

What is a metabolite library of standards?

A metabolite library of standards is a set of authentic, high purity compounds in plates, run on your own instrument. Recording each standard gives you retention times and spectra to identify metabolites in real samples with confidence.

Which IROA library should I start with?

Most labs start with MSMLS, the 600 primary metabolites behind untargeted LC-MS studies. Then they add a focused library for their field, such as GUTMLS for the microbiome or ONCOMLS for cancer metabolism.

What is the difference between MSMLS and LSMLS?

MSMLS and LSMLS hold the same 600 metabolites in the same plate positions. MSMLS gives 5 µg per well for LC-MS libraries, and LSMLS gives 1 mg per well for NMR, cell assays and screening.

Do the IROA libraries share compounds?

Some standards appear in more than one IROA library, mostly common central metabolites. The overlap chart on this page shows how many standards each pair of libraries shares, so you can avoid buying the same compound twice.

How do I check whether a library contains my metabolite?

Type the name, formula or HMDB ID into the compound finder on this page to see every IROA library that holds it. Each library page also has its full plate map to download.

What comes with every IROA library?

Every IROA library ships dried in 96-well plates with a plate map, a user manual and MLSDiscovery software. Each standard is above 95% purity and pre-weighed, 5 µg per well or 1 mg for LSMLS.

Why are authentic metabolite standards important?

Authentic standards give the true retention time, mass and spectrum of a metabolite on your own instrument. Matching against them removes the guesswork of database-only identification.

Which metabolite classes do the IROA libraries cover?

The IROA libraries span primary metabolism and nine focused areas of chemistry. They cover amino acids and peptides, organic acids, sugars, nucleotides, fatty acids, bile acids and sterols, oncometabolites, microbiome metabolites, polyphenols and plant compounds.

Which instruments can I use the libraries on?

The 5 µg libraries suit LC-MS and GC-MS, where a few micrograms give many injections. LSMLS adds enough material for NMR, cell assays and concentrated stock solutions.

Are the libraries sold by Sigma-Aldrich the same products?

Yes, IROA Technologies makes these libraries and Sigma-Aldrich distributes them. Buying direct from IROA gets you the manufacturer price and support from the team that builds the plates.